¡¤Automated calibration Automated gain ¡¤Automated make video of test process and play ¡¤DAC AVG & B scan ¡¤High-speed capture and very low noise ¡¤Solid metal housing (IP65) ¡¤High contrast viewing of the waveform from bright ¡¤Powerful pc software and reports can be export to excel
Features : ¡¤ Automated display precise flaw location(Depth d¡¢level p¡¢distance s¡¢amplitude¡¢sz dB¡¢§æ) ¡¤ Automated switch three staff gauge ((Depth d¡¢level p¡¢distance s) ¡¤ Automated calibration of transducer Zero-point, Angles, Front edge and material Velocity ¡¤ Convenient to make and use DAC and AVG to evaluate the echo,the curve can be modified and compensated ¡¤ Ten independence setup, any criterion can be input freely, we can work in the scene without test block
¡¤ Big memory of 300 A graph and 30000 thickness value ¡¤ Automated gain and gain scan ¡¤ Automated make video of test process and play ¡¤ Peak Hold and Peak Memory ¡¤ B scan ¡¤ Powerful pc software and reports can be export to excel ¡¤ The embeded software can be online updated ¡¤ Li battery, continue working time up to 7 hours
Other Assistant Function : ¡¤ Display freeze; ¡¤ Automated echo degree; ¡¤ Angles and K-value; ¡¤ Lock and unlock function of system parameters; ¡¤ Dormancy and screen savers; ¡¤ Electronic clock calendar ; ¡¤ Two gates setting and alarm indication; ¡¤ Gate and DAC alarm;
Specification :
|
Title |
Parameter |
Title |
Parameter |
|
Measuring Range£¨mm£© |
2.5 ¡« 10000 |
Measurement Mode |
Single¡¢Dual¡¢Thru |
|
Vertical Linearity Error |
¡Ü3% |
Reject |
0~80% |
|
Horizontal Linearity Error |
¡Ü0.1% |
Pulse Displacement£¨¦Ìs£© |
-20 ¡« +3400 |
|
Sensitivity Leavings |
¡Ý62dB |
Zero£¨¦Ìs£© |
0.0 ¡« 99.99 |
|
Dynamic range |
¡Ý34dB |
Port Type |
BNC |
|
Resolving Power |
¡Ý36dB |
Operating Temperature (¡æ) |
-20¡«50 |
|
Frequency Range£¨MHz£© |
0.5 ¡« 20 |
H¡ÁW¡ÁD(mm) |
210¡Á156¡Á40 |
|
Gain£¨dB£© |
0 ¡« 110 |
Weight£¨kg£© |
1.2 |
|
Material Velocity£¨m/s£© |
1000 ¡« 13000 |
|
|
Sandard Delivery:
Main unit
2.5MHZ-§æ20 straight probe
4MHZ-8x9mm, 60degree angle probe
4A/9Vpower adapter
Probe connection cable (Q9 to Q9)
Probe connection cable (Q9 to C5)
Instruction manual
Carrying case
Additional Accessories:
Data managing software
Data managing cables RS232
Straight probe (5MHZ-§æ20)
Straight probe (2.5MHZ-§æ20)
Straight probe (2.25MHZ-§æ20)
Straight probe (1MHZ-§æ20)
Angle probe (4MHZ-45degree, 8*9mm)
Angle probe (4MHZ-60degree, 8*9mm)
Angle probe (4MHZ-70degree, 8*9mm)
Angle probe (4MHZ-80degree, 8*9mm)
Angle probe (2MHZ-45degree, 8*9mm)
Angle probe (2MHZ-60degree, 8*9mm)
Angle probe (2MHZ-70degree, 8*9mm)
Angle probe (2MHZ-80degree, 8*9mm)
Probe T/R (5MHz-§æ20mm, focus 15mm)
Probe T/R (2.5MHz-§æ20mm, focus 15mm)
Connection cable to probe (Q9-Q9)
Connection cable to probe (Q9-C5)
Connection cable to probe (C9-Q9)
Connection cable to probe C9-C5)
Lithium ion battery
Power adapter (4A/9V)
Power Cable
Leather case
|